From within the Windows command prompt: cd C:\Program Files\Cinterion\Module Exchange Suite |
C:\Program Files\Cinterion\Module Exchange Suite> OK |
C:\Program Files\Cinterion\Module Exchange Suite> MESPort com3 |
COM3 successfully set (This actual my USB -> Serial) OK |
I copyed the MIDLETS into this directory C:\Program Files\Cinterion\Module Exchange Suite> MESCopy.exe Midlet_EHSX.jar mod:A:Midlet_EHSX.jar |
Midlet_EHSX.jad
1 files copied OK |
I copyed the MIDLETS into this directory C:\Program Files\Cinterion\Module Exchange Suite> MESCopy.exe Midlet_EHSX.jad mod:A:Midlet_EHSX.jad |
Midlet_EHSX.jar
1 files copied OK |
AT^SFSA="ls","a:/"
|
^SFSA: "m2m/" ^SFSA: "Midlet_EHSX.jar" ^SFSA: "Midlet_EHSX.jad" ^SFSA: 0 OK 1 files copied OK |
AT^SFSA="stat","a:/Midlet_EHSX.jar"
|
^SFSA: 109488 ^SFSA: "04/00/01,00:23:00" ^SFSA: "04/00/01,00:23:00" ^SFSA: "04/00/01,00:23:00" ^SFSA: 0 ^SFSA: 0 OK |
AT^SFSA="stat","a:/Midlet_EHSX.jad"
|
^SFSA: 278 ^SFSA: "04/00/01,00:22:00" ^SFSA: "04/00/01,00:22:00" ^SFSA: "04/00/01,00:22:00" ^SFSA: 0 ^SFSA: 0 OK |
AT^SJAM=0,"a:/Midlet_EHSX.jad","" |
OK |
AT^SJAM=1,"a:/Midlet_EHSX.jad","" |
OK |
AT^SJAM=4 |
^SJAM: "a:/Midlet_EHSX.jad","Midlet_EHSX","Vendor","1.0",0,111801,0 ^SJAM: "a:/JRC-1.56.30.jad","Java Remote Control MIDlet Suite","Cinterion","1.56.30",1,703294,0 OK |
AT^SJAM=5 |
^SJAM: "a:/JRC-1.56.30.jad","Java Remote Control MIDlet Suite","Cinterion","1.56.30",1 OK |